shiky8/my--cve-vulnerability-research

shiky8/my--cve-vulnerability-research

Releases0
Stars1
This repository contains information on all of the CVEs I found.

CVE History

CVEPublishedCVSS v3CVSS v2
6.5 MEDIUM6.4 MEDIUM

A security vulnerability has been detected in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. Affected is the function deletefile of the component FsBrowseClean. The manipulation of the argument dir/path leads to missing authorization. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

7.3 HIGH7.5 HIGH

A weakness has been identified in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. This impacts an unknown function of the file /fs. Executing a manipulation of the argument cwd can lead to unrestricted upload. The attack can be launched remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

4.3 MEDIUM5 MEDIUM

A security flaw has been discovered in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. This affects an unknown function. Performing a manipulation results in cross-site request forgery. The attack can be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

5.3 MEDIUM5 MEDIUM

A vulnerability was identified in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. The impacted element is an unknown function of the file /fs of the component Configuration Data Handler. Such manipulation of the argument File leads to information disclosure. It is possible to launch the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.

7.3 HIGH7.5 HIGH

A vulnerability was determined in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. The affected element is the function index_config of the file /LoginCB. This manipulation causes improper authentication. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.

7.3 HIGH7.5 HIGH

A vulnerability was found in Technostrobe HI-LED-WR120-G2 5.5.0.1R6.03.30. Impacted is an unknown function of the file /Technostrobe/ of the component Endpoint. The manipulation results in improper access controls. The attack may be performed from remote. The exploit has been made public and could be used. Multiple endpoints are affected. The vendor was contacted early about this disclosure but did not respond in any way.

6.5 MEDIUM

The web management interface in ETL Systems Ltd DEXTRA Series ' Digital L-Band Distribution System v1.8 does not implement Cross-Site Request Forgery (CSRF) protection mechanisms (no tokens, no Origin/Referer validation) on critical configuration endpoints.

7.5 HIGH

Incorrect access control in Comtech EF Data CDM-625 / CDM-625A Advanced Satellite Modem with firmware v2.5.1 allows attackers to change the Administrator password and escalate privileges via sending a crafted POST request to /Forms/admin_access_1.

7.5 HIGH

Incorrect access control in DEV Systemtechnik GmbH DEV 7113 RF over Fiber Distribution System 32-0078 H.01 allows unauthenticated attackers to access an administrative endpoint.

8.8 HIGH

CSRF vulnerability in narda miteq Uplink Power Contril Unit UPC2 v.1.17 allows a remote attacker to execute arbitrary code via the Web-based management interface and specifically the /system_setup.htm, /set_clock.htm, /receiver_setup.htm, /cal.htm?..., and /channel_setup.htm endpoints

6.5 MEDIUM

An issue was discovered in bridgetech VBC Server & Element Manager, firmware version 6.5.0-10 , 6.5.0-9, allowing unauthorized attackers to delete and create arbitrary accounts.

9.8 CRITICAL

The QVidium Opera11 device (firmware version 2.9.0-Ax4x-opera11) is vulnerable to Remote Code Execution (RCE) due to improper input validation on the /cgi-bin/net_ping.cgi endpoint. An attacker can exploit this vulnerability by sending a specially crafted GET request with a malicious parameter to inject arbitrary commands. These commands are executed with root privileges, allowing attackers to gain full control over the device. This poses a significant security risk to any device running this software.

6.5 MEDIUM

GatesAir Flexiva-LX devices on firmware 1.0.13 and 2.0, including models LX100, LX300, LX600, and LX1000, expose sensitive session identifiers (sid) in the publicly accessible log file located at /log/Flexiva%20LX.log. An unauthenticated attacker can retrieve valid session IDs and hijack sessions without providing any credentials. This attack requires the legitimate user (admin) to have previously closed the browser window without logging out.

6.1 MEDIUM

Stored cross-site scripting vulnerability in bridgetech VBC Server & Element Manager, firmware versions 6.5.0-9 thru 6.5.0-10, allows attackers to execute arbitrary code via the addName parameter to the /vbc/core/userSetupDoc/userSetupDoc endpoint.

9.8 CRITICAL

The Newtec Celox UHD (models: CELOXA504, CELOXA820) running firmware version celox-21.6.13 is vulnerable to an authentication bypass. An attacker can exploit this issue by modifying intercepted responses from the /celoxservice endpoint. By injecting a forged response body during the loginWithUserName flow, the attacker can gain Superuser or Operator access without providing valid credentials.

7.5 HIGH

The ELCA Star Transmitter Remote Control firmware 1.25 for STAR150, BP1000, STAR300, STAR2000, STAR1000, STAR500, and possibly other models, contains an information disclosure vulnerability allowing unauthenticated attackers to retrieve admin credentials and system settings via an unprotected /setup.xml endpoint. The admin password is stored in plaintext under the <p05> XML tag, potentially leading to remote compromise of the transmitter system.

7.5 HIGH

An issue was discovered in bridgetech probes VB220 IP Network Probe,VB120 Embedded IP + RF Probe, VB330 High-Capacity Probe, VB440 ST 2110 Production Analytics Probe, and NOMAD, firmware versions 6.5.0-9, allowing attackers to gain sensitive information such as administrator passwords via the /probe/core/setup/passwd endpoint. NOTE: the Supplier disagrees that 6.5.0-9 is affected, and instead reports that 5.6.0-3 and earlier are affected, and 5.6.0-4 (2020-09-21) and later are fixed.

7.5 HIGH

An issue was discovered in bridgetech VB288 Objective QoE Content Extractor, firmware version 5.6.0-8, allowing attackers to gain sensitive information such as administrator passwords via the /probe/core/setup/passwd endpoint.

9.8 CRITICAL

The R.V.R Elettronica TEX product (firmware TEXL-000400, Web GUI TLAN-000400) is vulnerable to broken access control due to improper authentication checks on the /_Passwd.html endpoint. An attacker can send an unauthenticated POST request to change the Admin, Operator, and User passwords, resulting in complete system compromise.

9.8 CRITICAL

An authentication bypass issue was discovered in Dasan Switch DS2924 web based interface, firmware versions 1.01.18 and 1.02.00, allowing attackers to gain escalated privileges via storing crafted cookies in the web browser.

10 CRITICAL

The Itel DAB Encoder (IDEnc build 25aec8d) is vulnerable to Authentication Bypass due to improper JWT validation across devices. Attackers can reuse a valid JWT token obtained from one device to authenticate and gain administrative access to any other device running the same firmware, even if the passwords and networks are different. This allows full compromise of affected devices.

9.8 CRITICAL

The Axel Technology StreamerMAX MK II devices (firmware versions 0.8.5 to 1.0.3) are vulnerable to Broken Access Control due to missing authentication on the /cgi-bin/gstFcgi.fcgi endpoint. Unauthenticated remote attackers can list user accounts, create new administrative users, delete users, and modify system settings, leading to full compromise of the device.

9.1 CRITICAL

The Axel Technology puma devices (firmware versions 0.8.5 to 1.0.3) are vulnerable to Broken Access Control due to missing authentication on the /cgi-bin/gstFcgi.fcgi endpoint. Unauthenticated remote attackers can list user accounts, create new administrative users, delete users, and modify system settings, leading to full compromise of the device.

7.2 HIGH

The Sound4 FIRST web-based management interface is vulnerable to Remote Code Execution (RCE) via a malicious firmware update package. The update mechanism fails to validate the integrity of manual.sh, allowing an attacker to inject arbitrary commands by modifying this script and repackaging the firmware.

7.5 HIGH

The ITEL ISO FM SFN Adapter (firmware ISO2 2.0.0.0, WebServer 2.0) is vulnerable to session hijacking due to improper session management on the /home.html endpoint. An attacker can access an active session without authentication, allowing them to control the device, modify configurations, and compromise system integrity.

9.8 CRITICAL

The Axel Technology WOLF1MS and WOLF2MS devices (firmware versions 0.8.5 to 1.0.3) are vulnerable to Broken Access Control due to missing authentication on the /cgi-bin/gstFcgi.fcgi endpoint. Unauthenticated remote attackers can list user accounts, create new administrative users, delete users, and modify system settings, leading to full compromise of the device.

7.2 HIGH

The Sound4 IMPACT web-based management interface is vulnerable to Remote Code Execution (RCE) via a malicious firmware update package. The update mechanism fails to validate the integrity of manual.sh, allowing an attacker to inject arbitrary commands by modifying this script and repackaging the firmware.

5.4 MEDIUM

The Mozart FM Transmitter web management interface on version WEBMOZZI-00287, contains a reflected Cross-Site Scripting (XSS) vulnerability in the /main0.php endpoint. By injecting a malicious JavaScript payload into the ?m= query parameter, an attacker can execute arbitrary code in the victim's browser, potentially stealing sensitive information, hijacking sessions, or performing unauthorized actions.

9.8 CRITICAL

The Itel DAB MUX (IDMUX build c041640a) is vulnerable to Authentication Bypass due to improper JWT validation across devices. Attackers can reuse a valid JWT token obtained from one device to authenticate and gain administrative access to any other device running the same firmware, even if the passwords and networks are different. This allows full compromise of affected devices.

10 CRITICAL

The Itel DAB Gateway (IDGat build c041640a) is vulnerable to Authentication Bypass due to improper JWT validation across devices. Attackers can reuse a valid JWT token obtained from one device to authenticate and gain administrative access to any other device running the same firmware, even if the passwords and networks are different. This allows full compromise of affected devices.

9.8 CRITICAL

The Mozart FM Transmitter web management interface on version WEBMOZZI-00287, contains an unauthenticated file upload vulnerability in the /upload_file.php endpoint. An attacker can exploit this by sending a crafted POST request with a malicious file (e.g., a PHP webshell) to the server. The uploaded file is stored in the /upload/ directory, enabling remote code execution and full system compromise.

7.2 HIGH

The Mozart FM Transmitter web management interface on version WEBMOZZI-00287, contains an unrestricted file upload vulnerability in the /patch.php endpoint. An attacker with administrative credentials can upload arbitrary files (e.g., PHP webshells), which are stored in the /patch/ directory. This allows the attacker to execute arbitrary commands on the server, potentially leading to full system compromise.

5.7 MEDIUM

The Sencore SMP100 SMP Media Platform (firmware versions V4.2.160, V60.1.4, V60.1.29) is vulnerable to session hijacking due to improper session management on the /UserManagement.html endpoint. Attackers who are on the same network as the victim and have access to the target's logged-in session can access the endpoint and add new users without any authentication. This allows attackers to gain unauthorized access to the system and perform malicious activities.

9.8 CRITICAL

The Eurolab ELTS100_UBX device (firmware version ELTS100v1.UBX) is vulnerable to Broken Access Control due to missing authentication on critical administrative endpoints. Attackers can directly access and modify sensitive system and network configurations, upload firmware, and execute unauthorized actions without any form of authentication. This vulnerability allows remote attackers to fully compromise the device, control its functionality, and disrupt its operation.

8.8 HIGH

Creacast Creabox Manager 4.4.4 contains a critical Remote Code Execution vulnerability accessible via the edit.php endpoint. An authenticated attacker can inject arbitrary Lua code into the configuration, which is then executed on the server. This allows full system compromise, including reverse shell execution or arbitrary command execution.

9.8 CRITICAL

The Blackmagic Web Presenter HD firmware version 3.3 exposes sensitive information via an unauthenticated Telnet service on port 9977. When connected, the service reveals extensive device configuration data including: - Model, version, and unique identifiers - Network settings including IP, MAC, DNS - Current stream platform, stream key, and streaming URL - Audio/video configuration This data can be used to hijack live streams or perform network reconnaissance.

6.8 MEDIUM

The 2wcom IP-4c 2.15.5 device suffers from a Broken Access Control vulnerability. Certain sensitive endpoints are intended to be accessible only after the admin explicitly grants access to a manager-level account. However, a manager-level user can bypass these controls by intercepting and modifying requests.

9.8 CRITICAL

The Blackmagic ATEM Mini Pro 2.7 exposes sensitive device and stream configuration information via an unauthenticated Telnet service on port 9990. Upon connection, the attacker can access a protocol preamble that leaks the video mode, routing configuration, input/output labels, device model, and even internal identifiers such as the unique ID. This can be used for reconnaissance and planning further attacks.

7.5 HIGH

The Blackmagic ATEM Mini Pro 2.7 exposes an undocumented Telnet service on TCP port 9993, which accepts unauthenticated plaintext commands for controlling streaming, recording, formatting storage devices, and system reboot. This interface, referred to as the "ATEM Ethernet Protocol 1.0", provides complete device control without requiring credentials or encryption. An attacker on the same network (or with remote access to the exposed port) can exploit this interface to execute arbitrary streaming commands, erase disks, or shut down the device - effectively gaining full remote control.

8.8 HIGH

In 2wcom IP-4c 2.16, the web interface allows admin and manager users to execute arbitrary code as root via a ping or traceroute field on the TCP/IP screen.

8.8 HIGH

The Sound4 PULSE-ECO AES67 1.22 web-based management interface is vulnerable to Remote Code Execution (RCE) via a malicious firmware update package. The update mechanism fails to validate the integrity of manual.sh, allowing an attacker to inject arbitrary commands by modifying this script and repackaging the firmware.

8.8 HIGH

Creacast Creabox Manager contains a critical authentication flaw that allows an attacker to bypass login validation. The system grants access when the username is creabox and the password begins with the string creacast, regardless of what follows.

7.5 HIGH

Creacast Creabox Manager 4.4.4 exposes sensitive configuration data via a publicly accessible endpoint /get. When accessed, this endpoint returns internal configuration including the creacodec.lua file, which contains plaintext admin credentials.

9.8 CRITICAL

Blackmagic Web Presenter version 3.3 exposes a Telnet service on port 9977 that accepts unauthenticated commands. This service allows remote attackers to manipulate stream settings, including changing video modes and possibly altering device functionality. No credentials or authentication mechanisms are required to interact with the Telnet interface.

6.5 MEDIUM

The 2wcom IP-4c 2.15.5 device's web interface includes an information disclosure vulnerability. By sending a crafted POST request to a specific endpoint (/cwi/ajax_request/get_data.php), an authenticated attacker (even with a low-privileged account like guest) can retrieve the hashed passwords for the admin, manager, and guest accounts. This significantly weakens the system's security posture, as these hashes could be cracked offline, granting attackers administrative access to the device.

9.8 CRITICAL

ENENSYS IPGuard v2 2.10.0 was discovered to contain hardcoded credentials.

9.8 CRITICAL

Missing authentication checks in the query.fcgi endpoint of NS3000 v8.1.1.125110 , v7.2.8.124852 , and v7.x and NS2000 v7.02.08 allows attackers to execute a session hijacking attack.

9.8 CRITICAL

Improper session management in the /login_ok.htm endpoint of DAEnetIP4 METO v1.25 allows attackers to execute a session hijacking attack.

9.8 CRITICAL

Improper session management in Elber REBLE310 Firmware v5.5.1.R , Equipment Model: REBLE310/RX10/4ASI allows attackers to execute a session hijacking attack.

8.8 HIGH

An issue in WorldCast Systems ECRESO FM/DAB/TV Transmitter v1.10.1 allows authenticated attackers to escalate privileges via a crafted JSON payload.

9.8 CRITICAL

Nautel VX Series transmitters VX SW v6.4.0 and below was discovered to contain a remote code execution (RCE) vulnerability in the firmware update process. This vulnerability allows attackers to execute arbitrary code via supplying a crafted update package to the /#/software/upgrades endpoint.

7.5 HIGH

An information disclosure vulnerability in the component /socket.io/1/websocket/ of Soundcraft Ui Series Model(s) Ui12 and Ui16 Firmware v1.0.7x and v1.0.5x allows attackers to access Administrator credentials in plaintext.

9.1 CRITICAL

Incorrect access control in BW Broadcast TX600 (14980), TX300 (32990) (31448), TX150, TX1000, TX30, and TX50 Hardware Version: 2, Software Version: 1.6.0, Control Version: 1.0, AIO Firmware Version: 1.7 allows attackers to access log files and extract session identifiers to execute a session hijacking attack.

9.1 CRITICAL

Incorrect access control in Itel Electronics IP Stream v1.7.0.6 allows unauthorized attackers to execute arbitrary commands with Administrator privileges.

7.5 HIGH

A credential exposure vulnerability in Electrolink 500W, 1kW, 2kW Medium DAB Transmitter Web v01.09, v01.08, v01.07, and Display v1.4, v1.2 allows unauthorized attackers to access credentials in plaintext.

9.1 CRITICAL

Incorrect access control in the HOME.php endpoint of JMBroadcast JMB0150 Firmware v1.0 allows attackers to access the Admin panel without authentication.

9.1 CRITICAL

Incorrect access control in JMBroadcast JMB0150 Firmware v1.0 allows attackers to access hardcoded administrator credentials.

9.8 CRITICAL

Incorrect access control in Orban OPTIMOD 5950 Firmware v1.0.0.2 and System v2.2.15 allows attackers to bypass authentication and gain Administrator privileges.