A vulnerability was found in D-Link DIR-816 A2 1.10CNB05_R1B011D88210. It has been declared as critical. This vulnerability affects unknown code of the file /goform/form2NetSniper.cgi. The manipulation leads to improper access controls. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

5.3 MEDIUM5 MEDIUM

A vulnerability was found in D-Link DIR-816 A2 1.10CNB05_R1B011D88210. It has been classified as critical. This affects an unknown part of the file /goform/form2LocalAclEditcfg.cgi of the component ACL Handler. The manipulation leads to improper access controls. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

5.3 MEDIUM5 MEDIUM

A vulnerability was found in D-Link DIR-816 A2 1.10CNB05_R1B011D88210 and classified as critical. Affected by this issue is some unknown functionality of the file /goform/form2IPQoSTcAdd of the component IP QoS Handler. The manipulation leads to improper access controls. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

5.3 MEDIUM5 MEDIUM

A vulnerability has been found in D-Link DIR-816 A2 1.10CNB05_R1B011D88210 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/form2Dhcpd.cgi of the component DHCPD Setting Handler. The manipulation leads to improper access controls. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

5.3 MEDIUM5 MEDIUM

A vulnerability, which was classified as critical, was found in D-Link DIR-816 A2 1.10CNB05_R1B011D88210. Affected is an unknown function of the file /goform/form2AdvanceSetup.cgi of the component WiFi Settings Handler. The manipulation leads to improper access controls. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

5.3 MEDIUM5 MEDIUM

A vulnerability classified as critical was found in D-Link DIR-816 A2 1.10CNB05_R1B011D88210. This vulnerability affects unknown code of the file /goform/DDNS of the component DDNS Service. The manipulation leads to improper access controls. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

5.3 MEDIUM5 MEDIUM

A vulnerability, which was classified as critical, has been found in D-Link DIR-816 A2 1.10CNB05_R1B011D88210. This issue affects some unknown processing of the file /goform/form2AddVrtsrv.cgi of the component Virtual Service Handler. The manipulation leads to improper access controls. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

7.3 HIGH7.5 HIGH

A vulnerability was found in D-Link DIR-823G 1.0.2B05_20181207. It has been rated as critical. This issue affects the function SetAutoRebootSettings/SetClientInfo/SetDMZSettings/SetFirewallSettings/SetParentsControlInfo/SetQoSSettings/SetVirtualServerSettings of the file /HNAP1/ of the component Web Management Interface. The manipulation leads to improper access controls. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in D-Link DIR-619L B1 2.06. Affected by this vulnerability is the function formVirtualServ of the file /goform/formVirtualServ. The manipulation of the argument curTime leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in D-Link DIR-619L B1 2.06. Affected is the function formSetWizardSelectMode of the file /goform/formSetWizardSelectMode. The manipulation of the argument curTime leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability was found in D-Link DIR-619L B1 2.06. It has been rated as critical. This issue affects the function formSetRoute of the file /goform/formSetRoute. The manipulation of the argument curTime leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability was found in D-Link DIR-619L B1 2.06. It has been declared as critical. This vulnerability affects the function formSetQoS of the file /goform/formSetQoS. The manipulation of the argument curTime leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability was found in D-Link DIR-619L B1 2.06. It has been classified as critical. This affects the function formSetPortTr of the file /goform/formSetPortTr. The manipulation of the argument curTime leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability was found in D-Link DIR-619L B1 2.06 and classified as critical. Affected by this issue is the function formSetPassword of the file /goform/formSetPassword. The manipulation of the argument curTime leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability has been found in D-Link DIR-619L B1 2.06 and classified as critical. Affected by this vulnerability is the function formSetMuti of the file /goform/formSetMuti. The manipulation of the argument curTime leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

5.5 MEDIUM5.2 MEDIUM

A vulnerability, which was classified as critical, was found in D-Link DIR-619L B1 2.06. Affected is the function formSetMACFilter of the file /goform/formSetMACFilter. The manipulation of the argument curTime leads to buffer overflow. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in D-Link DIR-619L B1 2.06. Affected by this issue is the function formSetLog of the file /goform/formSetLog. The manipulation of the argument curTime leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in D-Link DIR-619L B1 2.06. Affected by this vulnerability is the function formSetDDNS of the file /goform/formSetDDNS. The manipulation of the argument curTime leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in D-Link DIR-619L B1 2.06. Affected is the function formResetStatistic of the file /goform/formResetStatistic. The manipulation of the argument curTime leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability was found in D-Link DIR-619L B1 2.06. It has been rated as critical. This issue affects the function formLogDnsquery of the file /goform/formLogDnsquery. The manipulation of the argument curTime leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability was found in D-Link DIR-619L B1 2.06. It has been declared as critical. This vulnerability affects the function formEasySetupWWConfig of the file /goform/formEasySetupWWConfig. The manipulation of the argument curTime leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability was found in D-Link DIR-619L B1 2.06 and classified as critical. Affected by this issue is the function formEasySetTimezone of the file /goform/formEasySetTimezone. The manipulation of the argument curTime leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in D-Link DIR-619L B1 2.06. Affected is the function formAdvNetwork of the file /goform/formAdvNetwork. The manipulation of the argument curTime leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability has been found in D-Link DIR-619L B1 2.06 and classified as critical. Affected by this vulnerability is the function formEasySetPassword of the file /goform/formEasySetPassword. The manipulation of the argument curTime leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in D-Link DIR-619L B1 2.06. This issue affects the function formAdvFirewall of the file /goform/formAdvFirewall. The manipulation of the argument curTime leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in D-Link DIR-619L B1 2.06. This vulnerability affects the function formDeviceReboot of the file /goform/formDeviceReboot. The manipulation of the argument next_page leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

5.5 MEDIUM

TP-Link WR740N V6 has a stack overflow vulnerability via the ssid parameter in /userRpm/popupSiteSurveyRpm.htm url.

8.8 HIGH9 HIGH

A vulnerability has been found in D-Link DIR-605L 2.13B01 BETA and classified as critical. Affected by this vulnerability is the function formSetPassword of the file /goform/formSetPassword. The manipulation of the argument curTime leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in D-Link DIR-605L 2.13B01 BETA. Affected is the function formWlanWizardSetup of the file /goform/formWlanWizardSetup. The manipulation of the argument webpage leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in D-Link DIR-605L 2.13B01 BETA. This issue affects the function formWlanSetup_Wizard of the file /goform/formWlanSetup_Wizard. The manipulation of the argument webpage leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in D-Link DIR-605L 2.13B01 BETA. This vulnerability affects the function formSetWizard1/formSetWizard2. The manipulation of the argument curTime leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in D-Link DIR-605L 2.13B01 BETA. This affects the function formSetWAN_Wizard51/formSetWAN_Wizard52. The manipulation of the argument curTime leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability was found in D-Link DIR-605L 2.13B01 BETA. It has been classified as critical. Affected is the function formWlanSetup of the file /goform/formWlanSetup. The manipulation of the argument webpage leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability was found in D-Link DIR-605L 2.13B01 BETA and classified as critical. This issue affects the function formSetWanPPTP of the file /goform/formSetWanPPTP. The manipulation of the argument webpage leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability has been found in D-Link DIR-605L 2.13B01 BETA and classified as critical. This vulnerability affects the function formSetWanPPPoE of the file /goform/formSetWanPPPoE. The manipulation of the argument webpage leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in D-Link DIR-605L 2.13B01 BETA. This affects the function formSetEnableWizard of the file /goform/formSetEnableWizard. The manipulation of the argument curTime leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in D-Link DIR-605L 2.13B01 BETA. Affected by this issue is the function formSetEasy_Wizard of the file /goform/formSetEasy_Wizard. The manipulation of the argument curTime leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in D-Link DIR-605L 2.13B01 BETA. This affects the function formdumpeasysetup of the file /goform/formdumpeasysetup. The manipulation of the argument curTime leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability was found in D-Link DIR-605L 2.13B01 BETA. It has been rated as critical. Affected by this issue is the function formSetWanNonLogin of the file /goform/formSetWanNonLogin. The manipulation of the argument webpage leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability was found in D-Link DIR-605L 2.13B01 BETA. It has been declared as critical. Affected by this vulnerability is the function formSetWanL2TP of the file /goform/formSetWanL2TP. The manipulation of the argument webpage leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability was found in D-Link DIR-605L 2.13B01 BETA. It has been classified as critical. Affected is the function formLogDnsquery of the file /goform/formLogDnsquery. The manipulation of the argument curTime leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability was found in D-Link DIR-605L 2.13B01 BETA and classified as critical. This issue affects the function formEasySetupWizard/formEasySetupWizard2 of the file /goform/formEasySetupWizard. The manipulation of the argument curTime leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability was found in D-Link DIR-605L 2.13B01 BETA. It has been declared as critical. Affected by this vulnerability is the function formEasySetupWWConfig of the file /goform/formEasySetupWWConfig. The manipulation of the argument curTime leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability was found in D-Link DIR-605L 2.13B01 BETA. It has been classified as critical. Affected is the function formEasySetPassword of the file /goform/formEasySetPassword. The manipulation of the argument curTime leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability was found in D-Link DIR-605L 2.13B01 BETA and classified as critical. This issue affects the function formDeviceReboot of the file /goform/formDeviceReboot. The manipulation of the argument next_page leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

8.8 HIGH9 HIGH

A vulnerability has been found in D-Link DIR-605L 2.13B01 BETA and classified as critical. This vulnerability affects the function formAdvanceSetup of the file /goform/formAdvanceSetup. The manipulation of the argument webpage leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

8 HIGH

TP-Link WR941ND V6 has a stack overflow vulnerability in the ssid parameter in /userRpm/popupSiteSurveyRpm.htm.

6.5 MEDIUM6.8 MEDIUM

A vulnerability was found in TP-LINK TL-WR841ND up to 20240920. It has been rated as critical. Affected by this issue is some unknown functionality of the file /userRpm/popupSiteSurveyRpm.htm. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

8.1 HIGH7.6 HIGH

A vulnerability classified as critical was found in TOTOLINK AC1200 T8 4.1.5cu.861_B20230220. This vulnerability affects unknown code of the file /etc/shadow.sample. The manipulation leads to use of hard-coded password. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in TOTOLINK AC1200 T8 4.1.5cu.861_B20230220. This affects the function setWiFiRepeaterCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument password leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in TOTOLINK AC1200 T8 4.1.5cu.861_B20230220. It has been rated as critical. Affected by this issue is the function setWiFiMeshName of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument device_name leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in TOTOLINK AC1200 T8 and AC1200 T10 4.1.5cu.861_B20230220/4.1.8cu.5207. It has been declared as critical. Affected by this vulnerability is the function setStaticDhcpRules of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument desc leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in TOTOLINK AC1200 T8 and AC1200 T10 4.1.5cu.861_B20230220/4.1.8cu.5207. It has been classified as critical. Affected is the function setIpPortFilterRules of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument desc leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability has been found in TOTOLINK AC1200 T8 4.1.5cu.861_B20230220 and classified as critical. This vulnerability affects the function setParentalRules of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument slaveIpList leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

9.8 CRITICAL

TOTOLINK A3700R v9.1.2u.5822_B20200513 has a buffer overflow vulnerability in the http_host parameter in the loginauth function.

9.8 CRITICAL

TOTOLINK A3700R v9.1.2u.5822_B20200513 has a buffer overflow vulnerability in the ssid parameter in setWizardCfg function.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in TOTOLINK CP450 4.1.0cu.747_B20191224. Affected is the function loginauth of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument http_host leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-273558 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability, which was classified as critical, has been found in TOTOLINK CP900 6.3c.566. This issue affects the function setTelnetCfg of the component Telnet Service. The manipulation of the argument telnet_enabled leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-273557 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in TOTOLINK CP900 6.3c.566. This vulnerability affects the function UploadCustomModule of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument File leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-273556. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in TOTOLINK N350RT 9.3.5u.6139_B20201216. This affects the function setWizardCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument ssid leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-273555. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in TOTOLINK EX1200L 9.3.5u.6146_B20201023. This affects the function setParentalRules of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument week/sTime/eTime leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-273261 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in TOTOLINK EX200 4.0.3c.7646_B20201211. Affected by this vulnerability is the function loginauth of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument http_host leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-273259. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in TOTOLINK EX1200L 9.3.5u.6146_B20201023. Affected by this issue is the function loginauth of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument http_host leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-273260. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in TOTOLINK EX200 4.0.3c.7646_B20201211. Affected is the function getSaveConfig of the file /cgi-bin/cstecgi.cgi?action=save&setting. The manipulation of the argument http_host leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-273258 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

9.8 CRITICAL10 HIGH

A vulnerability was found in TOTOLINK CP450 4.1.0cu.747_B20191224. It has been classified as critical. This affects an unknown part of the file /web_cste/cgi-bin/product.ini of the component Telnet Service. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-273255. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in TOTOLINK A3300R 17.0.0cu.557_B20221024 and classified as critical. Affected by this issue is the function UploadCustomModule of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument File leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-273254 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability was found in TOTOLINK CA300-PoE 6.2c.884. It has been declared as critical. This vulnerability affects the function loginauth of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument password leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272788. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

2.6 LOW1.4 LOW

A vulnerability was found in TOTOLINK LR1200 9.3.1cu.2832. It has been classified as problematic. This affects an unknown part of the file /etc/shadow.sample. The manipulation leads to use of hard-coded password. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272787. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability was found in TOTOLINK LR1200 9.3.1cu.2832 and classified as critical. Affected by this issue is the function NTPSyncWithHost of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument host_time leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-272786 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability has been found in TOTOLINK LR350 9.3.5u.6369_B20220309 and classified as critical. Affected by this vulnerability is the function setWanCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument hostName leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272785 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in TOTOLINK A7000R 9.1.0u.6268_B20220504. Affected is the function setWizardCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument ssid leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272784. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in TOTOLINK A7000R 9.1.0u.6268_B20220504. This issue affects the function loginauth of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument password leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272783. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. It has been declared as critical. This vulnerability affects the function UploadCustomModule of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument File leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272608. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. It has been classified as critical. This affects the function setWiFiAclAddConfig of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument comment leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272607. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in TOTOLINK A3600R 4.1.2cu.5182_B20201102 and classified as critical. Affected by this issue is the function setWebWlanIdx of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument webWlanIdx leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-272606 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability has been found in TOTOLINK A3600R 4.1.2cu.5182_B20201102 and classified as critical. Affected by this vulnerability is the function setUrlFilterRules of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument url leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272605 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. Affected is the function setUploadSetting of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument FileName leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272604. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. This issue affects the function setUpgradeFW of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument FileName leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272603. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability classified as critical was found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. This vulnerability affects the function setTelnetCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument telnet_enabled leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-272602 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. This affects the function setPortForwardRules of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument comment leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. It has been declared as critical. Affected by this vulnerability is the function setMacQos of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument priority/macAddress leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272599. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. It has been rated as critical. Affected by this issue is the function setParentalRules of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument startTime/endTime leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. It has been classified as critical. Affected is the function setLanguageCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument langType leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-272598 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in TOTOLINK A3600R 4.1.2cu.5182_B20201102 and classified as critical. This issue affects the function setIpQosRules of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument comment leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272597 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability has been found in TOTOLINK A3600R 4.1.2cu.5182_B20201102 and classified as critical. This vulnerability affects the function setDiagnosisCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument ipDoamin leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272596. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. This affects the function setdeviceName of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument deviceMac/deviceName leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272595. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. Affected by this issue is the function loginauth of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument password/http_host leads to buffer overflow. The attack may be launched remotely. VDB-272594 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. Affected by this vulnerability is the function getSaveConfig of the file /cgi-bin/cstecgi.cgi?action=save&setting. The manipulation of the argument http_host leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272593 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability classified as critical has been found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. Affected is the function NTPSyncWithHost of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument hostTime leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272592. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

3.5 LOW2.7 LOW

A vulnerability was found in TOTOLINK A3000RU 5.9c.5185. It has been rated as problematic. This issue affects some unknown processing of the file /web_cste/cgi-bin/product.ini. The manipulation leads to use of hard-coded password. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272591. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability classified as critical has been found in TOTOLINK A3700R 9.1.2u.5822_B20200513. Affected is the function setWanCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument hostName leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-272574 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

5.5 MEDIUM4.9 MEDIUM

A vulnerability was found in TOTOLINK A3600R 4.1.2cu.5182_B20201102. It has been rated as critical. This issue affects some unknown processing of the file /web_cste/cgi-bin/product.ini of the component Telnet Service. The manipulation leads to use of hard-coded password. The exploit has been disclosed to the public and may be used. The identifier VDB-272573 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability was found in TOTOLINK A3100R 4.1.2cu.5050_B20200504. It has been declared as critical. This vulnerability affects the function setTelnetCfg of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument telnet_enabled leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272572. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in TOTOLINK A3100R 4.1.2cu.5050_B20200504. It has been classified as critical. This affects the function getSaveConfig of the file /cgi-bin/cstecgi.cgi?action=save&setting. The manipulation of the argument http_host leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272571. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

5.3 MEDIUM5 MEDIUM

A vulnerability was found in TOTOLINK A3700R 9.1.2u.5822_B20200513 and classified as problematic. Affected by this issue is some unknown functionality of the file /cgi-bin/ExportSettings.sh of the component apmib Configuration Handler. The manipulation leads to information disclosure. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-272570 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

2.5 LOW1 LOW

A vulnerability has been found in TOTOLINK A3300R 17.0.0cu.557_B20221024 and classified as problematic. Affected by this vulnerability is an unknown functionality of the file /etc/shadow.sample. The manipulation leads to use of hard-coded password. It is possible to launch the attack on the local host. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The identifier VDB-272569 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

4.3 MEDIUM4 MEDIUM

A vulnerability, which was classified as problematic, was found in TOTOLINK A3700R 9.1.2u.5822_B20200513. Affected is an unknown function of the file /wizard.html of the component Password Reset Handler. The manipulation leads to improper access controls. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272568. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in Tenda O3 1.0.0.10. Affected is the function fromDhcpSetSer. The manipulation of the argument dhcpEn/startIP/endIP/preDNS/altDNS/mask/gateway leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-272118 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability has been found in Tenda O3 1.0.0.10 and classified as critical. Affected by this vulnerability is the function fromVirtualSet. The manipulation of the argument ip/localPort/publicPort/app leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-272119. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in Tenda O3 1.0.0.10. This vulnerability affects the function formQosSet. The manipulation of the argument remark/ipRange/upSpeed/downSpeed/enable leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-272116. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in Tenda O3 1.0.0.10. This issue affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272117 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). Affected is the function formSetAutoPing. The manipulation of the argument ping1/ping2 leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-263082 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). This issue affects the function formOfflineSet of the file /goform/setStaOffline. The manipulation of the argument GO/ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263081 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been rated as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSe. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. Affected is the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262140. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. This issue affects the function formQosManage_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-262139. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. This vulnerability affects the function formQosManage_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). This affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The identifier VDB-262137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). Affected by this issue is the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this vulnerability is VDB-262136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in Tenda W9 1.0.0.7(4456). Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-262134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in Tenda W9 1.0.0.7(4456). Affected by this vulnerability is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. This issue affects the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262130 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability has been found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this vulnerability is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in Tenda AX1806 1.0.0.1. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262128. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in Tenda AX1803 1.0.0.1. This issue affects the function formSetSysToolDDNS of the file /goform/SetDDNSCfg. The manipulation of the argument serverName/ddnsUser/ddnsPwd/ddnsDomain leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in Tenda W30E 1.0/1.0.1.25. Affected is the function fromWizardHandle of the file /goform/WizardHandle. The manipulation of the argument PPW leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261990 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda 4G300 1.01.42. It has been declared as critical. This vulnerability affects the function sub_42775C/sub_4279CC. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-261988. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda 4G300 1.01.42. It has been classified as critical. This affects the function sub_4260F0. The manipulation of the argument upfilen leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-261987. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda 4G300 1.01.42 and classified as critical. Affected by this issue is the function sub_422AA4. The manipulation of the argument year/month/day/hour/minute/second leads to stack-based buffer overflow. The attack may be launched remotely. VDB-261986 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability has been found in Tenda 4G300 1.01.42 and classified as critical. Affected by this vulnerability is the function sub_41E858. The manipulation of the argument GO/page leads to stack-based buffer overflow. The attack can be launched remotely. The identifier VDB-261985 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in Tenda G3 15.11.0.17(9502). Affected is the function modifyDhcpRule of the file /goform/modifyDhcpRule. The manipulation of the argument bindDhcpIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261984. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in Tenda G3 15.11.0.17(9502). This issue affects the function formModifyPppAuthWhiteMac of the file /goform/ModifyPppAuthWhiteMac. The manipulation of the argument pppoeServerWhiteMacIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261983. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda W15E 15.11.0.14. It has been classified as critical. Affected is the function guestWifiRuleRefresh. The manipulation of the argument qosGuestDownstream leads to stack-based buffer overflow. It is possible to launch the attack remotely. VDB-261870 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. This issue affects the function formSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument manualTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261869 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. This vulnerability affects the function formSetStaticRoute of the file /goform/setStaticRoute. The manipulation of the argument staticRouteIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261868. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. This affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261867. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in Tenda W15E 15.11.0.14. Affected by this issue is the function formSetPortMapping of the file /goform/SetPortMapping. The manipulation of the argument portMappingServer/portMappingProtocol/portMappingWan/porMappingtInternal/portMappingExternal leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261866 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in Tenda W15E 15.11.0.14. Affected by this vulnerability is the function formSetDebugCfg of the file /goform/setDebugCfg. The manipulation of the argument enable/level/module leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261865 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in Tenda W15E 15.11.0.14. Affected is the function formQOSRuleDel. The manipulation of the argument qosIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The identifier of this vulnerability is VDB-261864. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda W15E 15.11.0.14. It has been rated as critical. This issue affects the function formIPMacBindModify of the file /goform/modifyIpMacBind. The manipulation of the argument IPMacBindRuleId/IPMacBindRuleIp/IPMacBindRuleMac/IPMacBindRuleRemark leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261863. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda W15E 15.11.0.14. It has been declared as critical. This vulnerability affects the function formIPMacBindDel of the file /goform/delIpMacBind. The manipulation of the argument IPMacBindIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261862 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda W15E 15.11.0.14. It has been classified as critical. This affects the function formIPMacBindAdd of the file /goform/addIpMacBind. The manipulation of the argument IPMacBindRule leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261861 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this issue is the function formDelPortMapping of the file /goform/DelPortMapping. The manipulation of the argument portMappingIndex leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261860. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability has been found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this vulnerability is the function formDelDhcpRule of the file /goform/DelDhcpRule. The manipulation of the argument delDhcpIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261859. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in Tenda W15E 15.11.0.14. Affected is the function formAddDnsForward of the file /goform/AddDnsForward. The manipulation of the argument DnsForwardRule leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261858 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in Tenda TX9 22.03.02.10. This issue affects the function sub_42C014 of the file /goform/PowerSaveSet. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in Tenda TX9 22.03.02.10. This vulnerability affects the function sub_42D4DC of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261856. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in Tenda TX9 22.03.02.10. This affects the function sub_42CB94 of the file /goform/SetVirtualServerCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261855. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda TX9 22.03.02.10. It has been rated as critical. Affected by this issue is the function sub_42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261854 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261792. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261791. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

5.9 MEDIUM

Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone function.

7.5 HIGH

Tenda AC10 v4.0 V16.03.10.13 and V16.03.10.20 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.

6.5 MEDIUM

Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function.

9.8 CRITICAL

Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo function.

3.8 LOW

Tenda AC500 V2.0.1.9(1307) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.

8 HIGH

Tenda AC15 v15.03.20_multi, v15.03.05.19, and v15.03.05.18 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.

8.8 HIGH

Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.

4.7 MEDIUM

Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.

6.5 MEDIUM

Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.

8.8 HIGH

Tenda W30E v1.0 V1.0.1.25(633) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.

8 HIGH

Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromDhcpListClient function.

7.5 HIGH

Tenda W30E v1.0 firmware v1.0.1.25(633) has a stack overflow vulnerability via the page parameter in the fromNatlimit function.

8.8 HIGH

Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.

5.7 MEDIUM

Tenda AC10U v1.0 Firmware v15.03.06.49 has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.

6.3 MEDIUM

Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.

6.3 MEDIUM

Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromwebExcptypemanFilter function.

6.7 MEDIUM

Tenda W30E v1.0 v1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromAddressNat function.

6.5 MEDIUM

Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the qos parameter in the fromqossetting function.

6.3 MEDIUM

Tenda FH1202 v1.2.0.14(408) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter.

7.3 HIGH

Tenda FH1203 V2.0.1.6 firmware has a command injection vulnerablility in formexeCommand function via the cmdinput parameter.

8 HIGH

Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the password parameter in the formaddUserName function.

9.8 CRITICAL

Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromVirtualSer function.

8.8 HIGH

Tenda AC7V1.0 v15.03.06.44 firmware contains a command injection vulnerablility in formexeCommand function via the cmdinput parameter.

7.4 HIGH

Tenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.

8 HIGH

Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the PPW parameter of the fromWizardHandle function.

9.8 CRITICAL

Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.

6.5 MEDIUM

Tenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the adslPwd parameter of the formWanParameterSetting function.

5.7 MEDIUM

Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the adslPwd parameter of the formWanParameterSetting function.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261144. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been rated as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-261143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been classified as critical. This affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-261141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability has been found in Tenda W30E 1.0.1.25(633) and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-260914 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in Tenda F1202 1.2.0.20(408). Affected by this issue is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260912. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in Tenda F1202 1.2.0.20(408). Affected by this vulnerability is the function fromqossetting of the file /goform/fromqossetting. The manipulation of the argument qos leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260911. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in Tenda F1202 1.2.0.20(408). Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-260910 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda F1202 1.2.0.20(408). It has been rated as critical. This issue affects the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260909 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda W20E 15.11.0.6. It has been declared as critical. This vulnerability affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260908. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.5 MEDIUM

A Stack Overflow vulnerability in Tenda AC15 v15.03.05.18 allows attackers to cause a denial of service via the LISTEN parameter in the fromDhcpListClient function.

8 HIGH

Tenda AC15V1.0 V15.03.20_multi has a command injection vulnerability via the deviceName parameter.

8 HIGH

Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the mitInterface parameter in the fromAddressNat function.

4.3 MEDIUM

Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the entrys parameter in the fromAddressNat function.

8.8 HIGH

Tenda F1202 v1.2.0.20(408) has a command injection vulnerablility in the formWriteFacMac function in the mac parameter.

6.5 MEDIUM

Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the PPPOEPassword parameter in the formQuickIndex function.

9.8 CRITICAL

Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability located in the funcpara1 parameter in the formSetCfm function.

6.5 MEDIUM

Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability in the page parameter of fromAddressNat function.

6.5 MEDIUM

Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the security parameter from the formWifiBasicSet function.

6.5 MEDIUM

Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the security_5g parameter from formWifiBasicSet function.

4.3 MEDIUM

Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the schedStartTime parameter from setSchedWifi function.

9.8 CRITICAL

Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the time parameter from saveParentControlInfo function.

5.7 MEDIUM

Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the list1 parameter from fromDhcpListClient function.

9.8 CRITICAL

Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the page parameter from fromAddressNat function.

8.8 HIGH

Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the deviceId parameter from saveParentControlInfo function.

8 HIGH

Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the schedEndTime parameter from setSchedWifi function.

8 HIGH

Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the entrys parameter from fromAddressNat function.

8.8 HIGH

Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the urls parameter from saveParentControlInfo function.

6.5 MEDIUM

Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the page parameter from fromDhcpListClient function.

9.8 CRITICAL

Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the mitInterface parameter from fromAddressNat function.

4.3 MEDIUM

Tenda AC15 v15.03.05.18 has a stack overflow vulnerability in the time parameter from the setSmartPowerManagement function.

6.5 MEDIUM

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the urls parameter of the saveParentControlInfo function.

6.5 MEDIUM

Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability in the security_5g parameter of the formWifiBasicSet function.

6.5 MEDIUM

Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability in the security parameter of the formWifiBasicSet function.

7.5 HIGH

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the list1 parameter of the fromDhcpListClient function.

8.1 HIGH

Tenda AC10U v15.03.06.48 has a stack overflow vulnerability in the deviceId, limitSpeed, limitSpeedUp parameter from formSetClientState function.

9.8 CRITICAL

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function.

8 HIGH

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the time parameter of the saveParentControlInfo function.

8 HIGH

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the schedEndTime parameter of the setSchedWifi function.

8.8 HIGH

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the deviceMac parameter of the addWifiMacFilter function.

4.3 MEDIUM

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function.

6.5 MEDIUM

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceId parameter of the saveParentControlInfo function.

9.8 CRITICAL

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the security parameter of the formWifiBasicSet function.

8 HIGH

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the page parameter of the fromDhcpListClient function.

6.5 MEDIUM

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the security_5g parameter of the formWifiBasicSet function.

9.8 CRITICAL

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the urls parameter of the saveParentControlInfo function.

8 HIGH

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the page parameter of the fromAddressNat function.

8.8 HIGH

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the time parameter of the saveParentControlInfo function.

6.5 MEDIUM

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the schedEndTime parameter of the setSchedWifi function.

9.8 CRITICAL

Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability in the entrys parameter of the fromAddressNat function.

8 HIGH

Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the deviceId parameter of the saveParentControlInfo function.

8 HIGH

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the mitInterface parameter of the fromAddressNat function.

6.5 MEDIUM

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceMac parameter of the addWifiMacFilter function.

9.8 CRITICAL

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceId parameter of the formSetDeviceName function.

9.8 CRITICAL

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability located in the deviceName parameter of the formSetDeviceName function.

9.8 CRITICAL

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceId parameter of the addWifiMacFilter function.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been declared as critical. This vulnerability affects the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258298 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258297 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this issue is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258296. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability has been found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258295. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in Tenda FH1205 2.0.0.7(775). Affected is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258294 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in Tenda FH1205 2.0.0.7(775). This issue affects the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258293 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258292. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda FH1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258163. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda FH1203 2.0.1.6. It has been classified as critical. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258162 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda FH1203 2.0.1.6 and classified as critical. This issue affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability has been found in Tenda FH1203 2.0.1.6 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in Tenda FH1203 2.0.1.6. This affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258159. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in Tenda FH1203 2.0.1.6. Affected by this issue is the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258158 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in Tenda FH1203 2.0.1.6. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258157 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258156. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258155. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been declared as critical. This vulnerability affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258154 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been classified as critical. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258153 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda FH1202 1.2.0.14(408) and classified as critical. Affected by this issue is the function formSetClientState of the file /goform/SetClientState. The manipulation of the argument deviceId/limitSpeed/limitSpeedUp leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258152. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

5.5 MEDIUM5.2 MEDIUM

A vulnerability has been found in Tenda FH1202 1.2.0.14(408) and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258151. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in Tenda FH1202 1.2.0.14(408). Affected is the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258150 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14(408). This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258149 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in Tenda F1203 2.0.1.6. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258148. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in Tenda F1203 2.0.1.6. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258147. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-258146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258145 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257946 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

7.5 HIGH

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the ssid parameter of form_fast_setting_wifi_set function.

9.8 CRITICAL

Tenda AC18 V15.03.05.05 contains a command injection vulnerablility in the deviceName parameter of formsetUsbUnload function.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function fromSetWifiGusetBasic of the file /goform/WifiGuestSet. The manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257945 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257944. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. This affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument deviceId/time/urls leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257943. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in Tenda AC7 15.03.06.44. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257941 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability classified as critical has been found in Tenda AC7 15.03.06.44. Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257940. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. This issue affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257939. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257934 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.05.19/15.03.20. Affected by this vulnerability is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257779. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257777 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formSetSambaConf of the file /goform/setsambacfg. The manipulation of the argument usbName leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257775. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

4.3 MEDIUM5 MEDIUM

A vulnerability classified as problematic was found in Tenda AC15 15.03.05.18. Affected by this vulnerability is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257671. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

4.3 MEDIUM5 MEDIUM

A vulnerability, which was classified as problematic, has been found in Tenda AC15 15.03.05.18. Affected by this issue is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257672. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in Tenda AC15 15.03.20_multi. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand of the component Cookie Handler. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257670 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been rated as critical. This issue affects the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257669 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function form_fast_setting_wifi_set of the file /goform/fast_setting_wifi_set. The manipulation of the argument ssid leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257668. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257667. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC15 15.03.20_multi and classified as critical. Affected by this issue is the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257666 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability has been found in Tenda AC15 15.03.05.18/15.03.20_multi and classified as critical. Affected by this vulnerability is the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257665 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in Tenda AC15 15.03.05.18/15.03.20_multi. Affected is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257664. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This issue affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257663. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in Tenda AC15 15.03.05.18/15.03.20_multi. This vulnerability affects the function formExpandDlnaFile of the file /goform/expandDlnaFile. The manipulation of the argument filePath leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257662 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in Tenda AC15 15.03.05.18/15.03.20_multi. This affects the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceId/deviceMac leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257661 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been rated as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257660. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.48. This affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument endIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257601 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.48. Affected by this issue is the function formSetCfm of the file goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257600. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC10U 15.03.06.48. It has been rated as critical. Affected by this issue is the function addWifiMacFilter of the file /goform/addWifiMacFilter. The manipulation of the argument deviceMac leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257462 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC10U 15.03.06.49. It has been declared as critical. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257461 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC10U 15.03.06.49. It has been classified as critical. Affected is the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257460. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257459. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.3 MEDIUM6.5 MEDIUM

A vulnerability has been found in Tenda AC10U 15.03.06.49 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257458 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, has been found in Tenda AC10U 1.0/15.03.06.49. Affected by this issue is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257456. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49. This affects the function formWifiWpsStart of the file /goform/WifiWpsStart. The manipulation of the argument index leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257457 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49. Affected by this vulnerability is the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257455. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49. Affected is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257454 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

6.5 MEDIUM

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the firewallEn parameter of formSetFirewallCfg function.

9.8 CRITICAL

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the page parameter of fromNatStaticSetting function.

4.3 MEDIUM

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the filePath parameter of formExpandDlnaFile function.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability.

4.3 MEDIUM5 MEDIUM

A vulnerability classified as problematic was found in Tenda AC18 15.03.05.05. Affected by this vulnerability is the function fromSysToolRestoreSet of the file /goform/SysToolRestoreSet. The manipulation leads to cross-site request forgery. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257059. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

4.3 MEDIUM5 MEDIUM

A vulnerability classified as problematic has been found in Tenda AC18 15.03.05.05. Affected is the function fromSysToolReboot of the file /goform/SysToolReboot. The manipulation leads to cross-site request forgery. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-257058 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257057 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function R7WebsSecurityHandler. The manipulation of the argument password leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257000. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability has been found in Tenda AC18 15.13.07.09 and classified as critical. Affected by this vulnerability is the function fromSetWirelessRepeat. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256999. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256896. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument startIP leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-256895. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC18 15.03.05.05. It has been classified as critical. This affects the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256893 was assigned to this vulnerability.

8.8 HIGH9 HIGH

A vulnerability was found in Tenda AC18 15.03.05.05 and classified as critical. Affected by this issue is the function formSetSpeedWan of the file /goform/SetSpeedWan. The manipulation of the argument speed_dir leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-256892. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

9.8 CRITICAL

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function.

9.8 CRITICAL

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function.